SMT General inspection standard (Part II)
Leadsintec will design a quality control product inspection based on product specifications and requirements you provide that fits within your budget.
Inspect Condition:
Put the SMT component semi-finished product under normal illumination that brightness above 800LUX, 1M directly below or 1M of 45W fluorescent lamp, and check it within 5 seconds at a distance of 45CM from the SMD semi-finished product in the direction of 45°-135°.
In addition, if it is impossible to see clearly under normal circumstances (for example, the component feet are dense and the body is too small), a magnifying glass should be used for observation. The specific requirements are as follows:
Land Width or Land Diameter | Inspection | Arbitration |
>1.0mm(0.039in) | 1.75X | 4X |
>0.5至1.0mm(0.020-0.039in) | 4X | 10X |
0.25至0.5mm(0.00984-0.020in) | 10X | 20X |
<0.25mm(0.00984in) | 20X | 40X |
Inspect tool:Magnifier Microscope X-RAY
Reference:《IPC-A-610E》Inspection standards.
PART (II)