1200w energy storage inverter power board

♦Input voltage range 19.6~33.6VDC

♦Maximum Continuous Current 69A

♦Rated voltage 100/110/120VAC±1% (settable)

♦Output frequency 50/60(± 0.1)Hz settable, default 60Hz

♦Rated power 1200W

♦P-boost support to drive 2200W resistive load.

♦Overload capacity: 101%~110% 3min
111%~130% 1min
131%~149% 1s
2200W 100ms

♦Rated current 12A

♦Output waveform Pure sine wave

♦THDu ≤2%@Linear Load, ≤4%Nonlinear Load
♦Efficiency Max 90%

Product Description

1200W portable outdoor energy storage power inverter board, the product set of inverter and charger integration, high efficiency, high quality, built-in EMI filter, low ripple noise, with over-current/over-voltage protection/over-temperature protection/short-circuit protection, etc., the power supply is equipped with a communication function, real-time uploading of power supply voltage, current, temperature, power, and other types of data and faults.

The role of inverters in energy storage systems

1, energy conversion: the inverter converts the DC electrical energy in the energy storage system into AC electrical energy to meet the demand of the grid or load. It converts the electrical energy in the energy storage system into usable forms of electrical energy to realize the effective use of energy.

2、Control and communication: the inverter can communicate and coordinate with other components of the energy storage system to achieve centralized control and management of the system. It can realize remote monitoring, fault diagnosis and performance optimization of the energy storage system by connecting with the energy management system or monitoring system.

3, isolation and protection: the inverter plays the role of isolation and protection between the energy storage system and the power grid. It separates the energy storage system from the external power grid, preventing the reverse flow of electricity or interference. At the same time, the inverter can also realize the protection of the energy storage system and power grid by monitoring the voltage, current and other parameters.

4, power control: the inverter can control the size and stability of the output power according to the load demand or grid requirements. Through the control of the inverter, the power regulation and optimization of the energy storage system can be realized to meet different power requirements.

Product Applications

Marine Solar Systems
Home Solar Power
Home Solar Power

Caravan Solar System

Charger parameter

Performance index ModelModelLST-24-120-1200
AC InputCharging Power1100
Input Voltage Range90~139VAC
Frequency Range40~70Hz
Maximum Input Current14A
PF0.99@ 100% load
THDi<5% @ 100% load
DC OutputMaximum charging current56A
Voltage Ripple≤500mV
Charging Range (Adjustable)19.6~33.6VDC ±0.05%
Charge managementcontrolled by host computer
Efficiency MAX89.50%
 

The main functions and performance indicators of the energy storage inverter

1、Power leveling active control mode, suitable for intermittent energy output power short-term fluctuation leveling;

2、Power leveling passive control mode, accepting the control of grid scheduling system, participating in the peak shaving and valley filling of the grid;

3、charging and discharging integrated design, according to the characteristics of the energy storage components can be selected charging and discharging strategy (such as constant current charging and discharging, constant power charging and discharging, automatic charging and discharging, etc.).

4、Grid-connected operation, reactive power automatic or dispatch compensation function, low voltage ride-through function.

5、Off-the-grid operation: independent power supply, adjustable voltage and frequency; power supply of multiple machines in parallel combination, power can be automatically distributed among multiple machines.

6、 with Ethernet, CAN and RS485 interfaces, providing open communication protocols to facilitate information interaction between BMS (battery management system) and monitoring system.

7、Complete protection function can protect the safety of converter and energy storage components under various fault conditions.